ScalaTexture™

ScalaTexture™ comprises a range of styles and visual effects appropriate for privacy applications where light diffusion and obscuration are desired.

  • icon descriptionPrivacy
  • icon descriptionDecorative
Features
icon description
Create Private & Illuminated SpacesScalaTexture™ diffuses the light that enters a space, transferring the very best qualities of natural light whilst blocking out onlookers.
Striking Designs without the PricetagScalaTexture™ offers a low-cost decorative touch to a room with a range of styles and visual effects to suit any setting.
Pattern Consistency & DurabilityOur options across the ScalaTexture™ range come with a consistent finish and high level of durability.
Product Range

*The maximum sheet size is a manufacturing size and may be in excess of the safe glazing sizes set out in Australian standards. **Image is for visual indication only.

Applications

External

  • Windows
  • Doors
  • Balustrades
  • Roof Glazing,
  • Frameless Glazing

Internal

  • Doors
  • Partitions
  • Shower Screens
  • Frameless Glazing
Downloads
Technical Information
Performance Data
Product Name Nominal Thickness Visible Solar UV Trans U-Value SHGC Shading Co. Weight m2
Trans. Refl. Out Refl. In Trans. Refl.
Satinlite 4 89 8 8 82 8 67 5.9 0.85 0.98 10
Satinlite 5 89 8 8 79 7 63 5.8 0.83 0.95 12.5
Satinlite 6 88 8 8 78 7 60 5.8 0.82 0.95 15
Spotswood 4 89 8 8 82 8 67 5.9 0.85 0.98 10
Spotswood 5 89 8 8 79 7 63 5.8 0.83 0.95 12.5
Spotswood 6 88 8 8 78 7 60 5.8 0.82 0.95 15
Cathlite 4 89 8 8 82 8 67 5.9 0.85 0.98 10
Cathlite 5 89 8 8 79 7 63 5.8 0.83 0.95 12.5
Product Name Nominal Thickness Visible Solar UV Trans U-Value SHGC Shading Co. Weight m2
Trans. Refl. Out Refl. In Trans. Refl. Air Argon
Satinlite™ + QFloat™ Clear 4+12+4 80 15 15 69 13 51 2.7 2.6 0.75 0.87 20
Satinlite™ + QFloat™ Clear 5+12+5 79 15 15 63 12 47 2.7 2.5 0.72 0.83 25
Satinlite™ + QFloat™ Clear 6+12+6 78 15 15 62 12 44 2.7 2.5 0.71 0.82 30
Spotswood™ + QFloat™ Clear 4+12+4 80 15 15 69 13 51 2.7 2.6 0.75 0.87 20
Spotswood™ + QFloat™ Clear 5+12+5 79 15 15 63 12 47 2.7 2.5 0.72 0.83 25
Spotswood™ + QFloat™ Clear 6+12+6 78 15 15 62 12 44 2.7 2.5 0.71 0.82 30
Cathlite™ + QFloat™ Clear 4+12+4 80 15 15 69 13 51 2.7 2.6 0.75 0.87 20
Cathlite™ + QFloat™ Clear 5+12+5 79 15 15 63 12 47 2.7 2.5 0.72 0.83 25
Satinlite™ + EnergyTech™ Clear (#3) 4+12+4 74 18 17 57 16 41 1.9 1.6 0.71 0.81 20
Satinlite™ + EnergyTech™ Clear (#3) 5+12+4 74 17 17 55 15 40 1.9 1.6 0.68 0.78 22.5
Satinlite™ + EnergyTech™ Clear (#3) 6+12+6 73 17 16 52 15 35 1.9 1.6 0.67 0.77 30
Spotswood™ + EnergyTech™ Clear (#3) 4+12+4 74 18 17 57 16 41 1.9 1.6 0.71 0.81 20
Spotswood™ + EnergyTech™ Clear (#3) 5+12+4 74 17 17 55 15 40 1.9 1.6 0.68 0.78 22.5
Spotswood™ + EnergyTech™ Clear (#3) 6+12+6 73 17 16 52 15 35 1.9 1.6 0.67 0.77 30
Cathlite™ + EnergyTech™ Clear (#3) 4+12+4 74 18 17 57 16 41 1.9 1.6 0.71 0.81 20
Cathlite™ + EnergyTech™ Clear (#3) 5+12+5 74 17 17 55 15 40 1.9 1.6 0.68 0.78 22.5
All performance data is determined using LBL Windows 5.2 software. NFRC 100-2001 conditions have been used.
Considerations

Thermal Risk
Always assess your chosen product for thermal risk prior to specifying.

How to Specify
Glass Thicknesses and colours available:
  • Satinlite4, 5, 6 & 6.76mm
  • Spotswood4, 5, & 6mm
  • Cathlite4, 5, & 6mm

Select from: Annealed, Heat Strengthened, Toughened or Toughened Heat Soaked

*If unsure, select in compliance with AS1288–2006 or manufacturers recommendation.*

The glass shall comply with the following performance criteria:

  • U value
  • Solar Heat Gain Coefficient (SHGC)
  • Visible Light Transmission %
  • Glass Only Values
  • Total window
Annealed 
Annealed glass is glass produced without internal stresses imparted by heat treatment, i.e., rapid cooling, or by toughening or heat strengthening. Annealed glass is not a Grade A safety glass.
Toughened
Glass converted to a safety glass by subjection to a process of pre-stressing so that, if fractured, the entire piece disintegrates into small, harmless particles. Toughened glass is a Grade A Safety Glass
Heat Soaking
Heat soak testing is a destructive test, which reduces the likelihood of spontaneous breakage by converting impurities such as nickel sulphide inclusions. Heat soaking is required in some but not all applications. If unsure, select in compliance with AS1288-2006 or manufacturers recommendation. 
Heat Strengthening

All glass which requires extra strength and thermal resistance will be heat strengthened. Heat strengthening increases the strength of annealed glass; however, it is not a substitute for toughened glass.

In the event of fracturing heat strengthened glass will crack and tends to remain in glazed position.

Toned Glass
Toned glass absorbs a proportion of solar radiation and may require a thermal assessment depending on application. 

All glass is to be selected and installed in accordance but not exclusively with the following Australian and/or New Zealand Standards

  • AS 1288 Glass in Buildings Selection and Installation
  • AS 1170 Minimum Wind Loads on Structures
  • AS/NZ 2208 Safety Glazing Materials in Buildings
  • AS/NZ 4666 Insulating Glass Units
  • AS/NZ 4667 Quality Requirements for cut-to-size and Processed Glass

 

Oceania Glass makes and distributes glass. Oceania Glass does not process glass nor produce Insulated Glass Units. Processing of glass and production of Insulated Glass Units is undertaken by independent processors. Speak with your nominated glass processors to understand their processing capability.