IntruderLam™

IntruderLam™ is a laminated Grade A safety glass available in two thicknesses, 6.52mm & 7.52mm, and provides extra resistance to penetration as its interlayer is four times thicker than normal laminated glass.

  • icon descriptionSecurity
Features
icon description
Safety & SecurityIntruderLam™ is specifically developed to offer a resilient and long-lasting barrier that resists penetration even upon breakage.
Create Beautiful SpacesThere are a range of options for colour, translucency and glass coating available within IntruderGuard™ – so you can create the aesthetic you desire.
Interior ProtectionIntruderLam™ reduces the rate at which your furniture fades by absorbing 99% of UV radiation.
Product Range

*The maximum sheet size is a manufacturing size and may be in excess of the safe glazing sizes set out in Australian standards. **Image is for visual indication only.

Applications

External

  • Doors
  • Windows
  • Shop Front
  • Frameless Glazing

Internal

  • Doors
  • Partitions
  • Shop Front
  • Frameless Glazing
Downloads
Technical Information
Performance Data
Product Name Nominal Thickness Visible Solar UV Trans U-Value SHGC Shading Co. Weight m2
Trans. Refl. Out Refl. In Trans. Refl.
IntruderLam™ Grey 7.52 42 5 5 44 55 <1 5.6 0.60 0.69 16.6
IntruderLam™ Grey 6.52 45 5 5 46 5 <1 5.6 0.61 0.71 13.9
IntruderLam™ Clear 6.52 88 8 8 72 7 <1 5.6 0.78 0.90 13.9
IntruderLam™ Clear 7.52 86 7 7 69 6 <1 5.6 0.77 0.88 16.6
Product Name Nominal Thickness Visible Solar UV Trans U-Value SHGC Shading Co. Weight m2
Trans. Refl. Out Refl. In Trans. Refl. Air Argon
IntruderLam™ Grey + QFloat™ Clear 6.52+12+6 38 7 13 41 7 <1 2.6 2.5 0.50 0.57 28.9
IntruderLam™ Grey + QFloat™ Clear 7.52+12+6 38 7 13 39 7 <1 2.6 2.5 0.49 0.56 31.6
IntruderLam™ Grey + EnergyTech™ Clear 6.52+12+6 35 7 14 30 7 <1 1.8 1.6 0.44 0.50 28.9
IntruderLam™ Grey + EnergyTech™ Clear 7.52+12+6 34 7 14 29 8 <1 1.8 1.6 0.43 0.49 31.6
IntruderLam™ Clear + QFloat™ Clear 6.52+12+6 78 14 14 57 11 <1 2.6 2.5 0.67 0.77 28.9
IntruderLam™ Clear + QFloat™ Clear 7.52+12+6 76 14 14 55 10 <1 2.6 2.5 0.65 0.75 31.6
IntruderLam™ Clear + EnergyTech™ Clear (#5) 6.52+12+6 72 17 16 50 12 <1 1.8 1.6 0.64 0.73 28.9
IntruderLam™ Clear + EnergyTech™ Clear (#5) 7.52+12+6 71 16 16 48 12 <1 1.8 1.6 0.62 0.71 31.6
All performance data is determined using LBL Windows 5.2 software. NFRC 100-2001 conditions have been used.
Considerations

IGUs
IntruderLam should be incorporated with window frames and locks of sufficient strength.

Installation
Exposed edges should be protected from moisture ingress. To provide a barrier to forced entry AssaultLam must be installed into a full frame without openings.

Glass Processing
Further processing is required for frameless glazing.

How to Specify
Glass Thicknesses and colours available:
  • Clear 6.52 & 7.52mm

Select from: Laminated or Heat Strengthened Laminated

*If unsure, select in compliance with AS1288–2006 or manufacturers recommendation.*

The glass shall comply with the following performance criteria:

  • U value
  • Solar Heat Gain Coefficient (SHGC)
  • Visible Light Transmission %
  • Glass Only Values
  • Total window
Heat Strengthening

All glass which requires extra strength and thermal resistance will be heat strengthened. Heat strengthening increases the strength of annealed glass; however, it is not a substitute for toughened glass.

In the event of fracturing heat strengthened glass will crack and tends to remain in glazed position.

Toned Glass

Toned glass absorbs a proportion of solar radiation and may require a thermal assessment depending on application.

All glass is to be selected and installed in accordance but not exclusively with the following Australian and/or New Zealand Standards

  • AS 1288 Glass in Buildings Selection and Installation
  • AS 1170 Minimum Wind Loads on Structures
  • AS/NZ 2208 Safety Glazing Materials in Buildings
  • AS/NZ 4666 Insulating Glass Units
  • AS/NZ 4667 Quality Requirements for cut-to-size and Processed Glass

 

Oceania Glass makes and distributes glass. Oceania Glass does not process glass nor produce Insulated Glass Units. Processing of glass and production of Insulated Glass Units is undertaken by independent processors. Speak with your nominated glass processors to understand their processing capability.